Going Safe As part of the checkout procedure, pressing the STOP switch, followed by pressing the RECORD switch and then pressing the RUN switch should result in the green SAFE indicator turning on. If this does not happen, a problem exists in the failsafe circuitry, mode switches or other parts of the RD379.